1. General description

VACZ5 series AC mv vacuum contactor is suitable for power system of AC tri-phase 50Hz, rated current 630 A and below, rated voltage 12kV and 7.2kV, for remotely making and breaking circuit, frequently starting and controlling AC motor. It also could be combined with fuse and protector to replace vacuum circuit breaker.

The vacuum contactor complies with GB/T 14808, IEC 60470 and JB/T 7122 standard, the main performance indicators have reached the international level.

The Technical Specifications of this vacuum contactor define its electrical and mechanical parameters for AC motor control and capacitor switching applications in medium-voltage power systems. This mv vacuum contactor is suitable for power systems of AC three-phase 50Hz with rated current up to 630A and rated voltage of 12kV and 7.2kV, designed for remotely making and breaking circuits, frequently starting and controlling AC motors. The 6kv-10kv vacuum contactor can also be combined with fuses and protectors to replace vacuum circuit breakers in certain applications. This vacuum contactor complies with GB/T 14808, IEC 60470, and JB/T 7122 standards, with main performance indicators reaching international levels. The mv vacuum contactor is available in rated currents of 160A, 250A, 400A, and 630A for both 7.2kV and 12kV voltage classes. This 6kv-10kv vacuum contactor offers 4s thermal stability current matching the rated current values, making capacity of up to 6000A per 100 operations, and breaking capacity of up to 5040A per 25 operations. Each vacuum contactor is ideal for frequent switching operations in demanding industrial environments. Proper installation of this mv vacuum contactor ensures reliable performance in switchgear and capacitor bank applications.

2. Main technical parameter

Item

Unit

VACZ5-160~630/7.2

VACZ5-160~630/12

Rated voltage

kV

7.2

12

Rated current

A

160

250

400

630

160

250

400

630

4s thermal stability current

A

160

250

400

630

160

250

400

630

Making capacity

A/100times

1600

2500

4000

6000

1600

2500

4000

6000

Breaking capacity

A/25times

1280

2000

3200

5040

1280

2000

3200

5040

Rated P.F. withstand voltage

kV

28

42

Rated lightning impulse withstand voltage(peak)

kV

60

75

Mechanical life time

times

1,000,000

Rated operation voltage

V

AC/DC 110,220,380

Rated operation frequency

times/h

300

Closing time

ms

≤80

Opening time

ms

≤40

Tri-phase asynchronous time

ms

≤2

Clearance between open contacts

mm

5.0±0.5

6.0±0.5

Over travel

mm

1.5±0.5

Each conductive loop resistance

μΩ

≤200