PRODUCT DESCRIPTION
EXJXF series wall-mounted distribution box below 400 is a new product introduced from ABB Company,with a compact and reasonable structure,which not only replaces the basic characteristics of FXF,but also reflects the development and direction of modern electrics.
EXJXF series wall-mounted distribution box below 400 is a power distribution unit that is assembled into various control functions according to component type,specification and quantity.The product is widely used in power system with rated voltage  of 380V  and  below,and  frequency  of  50Hz  in  industrial  and civil  construction,for  power  distribution.lighting distribution and automation control.
JXF series wall-mounted distribution box below 400 is m enclosed structure,mounted on wait or concealed in the wall.The box is made of cold-rolled steel plate by bending,the surface is disposed with electrostatic spray,both beautiful and protective.The box door and the box body are welded with ground screws and connected with multiple strands,with good grounding protection.The product'shell protection class is IP30,in line with GB7251-1 and IEC51439-1 and other standards.
The Technical Specifications of this JXF Wall Mounted Distribution Box define its mechanical and electrical parameters for low-voltage distribution applications. This Hanging Type Power Distribution Box features a compact and reasonable structure introduced from ABB Company, which not only replaces the basic characteristics of the FXF series but also reflects the development and direction of modern electrical design. The 380V Electrical Enclosure Box is a power distribution unit assembled into various control functions according to component type, specification, and quantity. This JXF Wall Mounted Distribution Box is widely used in power systems with rated voltage of 380V and below, and frequency of 50Hz in industrial and civil construction, for power distribution, lighting distribution, and automation control. The Hanging Type Power Distribution Box features an enclosed structure, mounted on the wall or concealed in the wall. Each 380V Electrical Enclosure Box is made of cold-rolled steel plate by bending, with electrostatic spray surface treatment. The JXF Wall Mounted Distribution Box ensures good grounding protection with welded ground screws. This Hanging Type Power Distribution Box meets the shell protection class IP30, in line with GB7251-1 and IEC51439-1 standards. The 380V Electrical Enclosure Box is an ideal choice for industrial and civil construction applications.
 
OVERALL DIMENSION
ModelThickness of
iron material 
Overall dimensions(mm)Size of  flush mountingSize of base plate installedNumber
of lock
HighWidthDeep HighWidthHighWidth
JXF-2520/141.2250 200 140 290 150 170 158 1
JXF-3025/141.2300 250 140 340 200 220 208 1
JXF-3025/181.2300 250 180 340 200 220 208 1
JXF-3030/141.2300 300 140 340 250 220 258 1
JXF-3030/181.2300 300 180 340 250 220 258 1
JXF-4030/141.2400 300 140 440 250 320 258 1
JXF-4030/201.2400 300 200 440 260 320 258 1
JXF-5040/141.5500 400 140 540 350 420 358 1
JXF-5040/201.5500 400 200 540 350 420 358 1
JXF-5040/231.5500 400 230 540 350 420 358 1
JXF-6040/141.5600 400 140 640 350 520 358 2
JXF-6040/201.5600 400 200 640 350 520 358 2
JXF-6040/231.5600 400 230 640 350 520 358 2
 
ModelThickness of
iron material 
Overall dimensions(mm)Size of  flush mountingSize of base plate installedNumber
of lock
HighWidthDeep HighWidthHighWidth
JXF-6050/141.5600 500 140 640 450 520 458 2
JXF-6050/201.5600 500 200 640 450 520 458 2
JXF-6050/231.5600 500 230 640 450 520 458 2
JXF7050/161.5700 500 160 740 450 620 458 2
JXF7050/201.5700 500 200 740 450 620 458 2
JXF7050/231.5700 500 230 740 450 620 458 2
JXF-8060/201.5800 600 200 840 550 720 558 2
JXF-8060/231.5800 600 230 840 550 720 558 2
JXF-8060/251.5800 600 250 840 550 720 558 2
JXF-10060/251.51000 300 200 1040 750 920 758 2
JXF-10080/301.51000 800 230 1040 750 920 758 2
1.51000 800 260 1040 750 920 758 2