0
EX85 lateral expansion inner cone
EX85 lateral expansion inner cone
EX85 lateral expansion inner cone
EX85 lateral expansion inner cone

Environmental Cabinet Accessories-85 lateral expansion inner cone

EX85 lateral expansion inner cone
Environmental Cabinet Series with 85 lateral expansion inner cone, rated voltage 12kV, withstand voltage 45kV, partial discharge 15kV ≤ 3pC, and red color.
Quantity:
Contact Now
add to cart

Detailed Description
Environmental Cabinet Series with EX85 lateral expansion inner cone, rated voltage 12kV, withstand voltage 45kV, partial discharge 15kV ≤ 3pC, and red color.

Technical Specifications

The Technical Specifications of this Environmental Cabinet Accessories product define its electrical performance parameters for medium-voltage switchgear applications. The rated voltage of 12kV and withstand voltage of 45kV establish the dielectric strength of this 85 lateral expansion inner cone, while the partial discharge level of 15kV ≤ 3pC ensures superior insulation quality with minimal internal defects. This 85 lateral expansion inner cone features a red-colored housing that facilitates phase identification in multi-phase switchgear assemblies. As a certified Switchgear Insulation Component, this Environmental Cabinet Accessories product is specifically designed for environmental cabinet installations, providing reliable lateral expansion connections between adjacent cabinet sections. The inner cone configuration of this 85 lateral expansion inner cone ensures secure mechanical engagement and consistent electrical contact. Each Switchgear Insulation Component undergoes routine partial discharge and high-voltage testing to verify compliance with stated specifications. Proper installation of this Environmental Cabinet Accessories component as a Switchgear Insulation Component ensures long-term reliability in 12kV indoor distribution networks. The compact design of this 85 lateral expansion inner cone allows for space-efficient integration into standard environmental cabinet configurations, making it an ideal choice for urban distribution applications.

                                                  Rated voltage                    Withstand voltage              Partial discharge               Color
                                                          12kV               45kV     15kV ≤ 3pC  red
 
85 lateral expansion inner cone technical specification chart with rated voltage 12kV withstand voltage 45kV partial discharge 15kV≤3pC and red color for environmental cabinet series bushing connection and gas-insulated switchgear extension

Send Message