ZW32-40.5M type outdoor pole-mounted reliable permanent magnet embedded type vcb (vacuum circuit breaker) adopts a unique permanent magnet mechanism, manual closing mechanism, and high reliable intelligent controller. This equipment mainly applies to medium voltage overhead line power grid. It is used for opening and closing load current, overload current, and short circuit current, with 0~3 times automatic reclosing.
Quantity:
Contact Now
add to cart
1. General description
  EXZW32-40.5M type outdoor pole-mounted reliable permanent magnet embedded type vcb (vacuum circuit breaker) adopts special design permanent magnet mechanism, manual closing mechanism and high reliable intelligent controller. This equipment mainly apply to medium voltage overhead line power grid. It is used for opening and closing load current, over load current and short circuit current, with 0~3 times automatic reclosing.
High reliability 
  • Maintenance free in entire service life
  • High mechanical life and electric life
  • The complete appliance has small volume, light weight, and easy for installation
  • Has standard relay protection and fast automatic relcosing function.

2. Using condition
  • Ambient air temperature::-30℃~+60℃;
  • Altitude:≤ 2000m;
  • Wind speed: ≤ 34m/s;
  • The vibration from the switch equipment and the external of the control equipment or earthquake can be ignored.
  • Pollution grade: IV class.
  • Storage temperature: -40℃~+85℃。
3. Main technical Parameter

circuit breaker main technical parameter
ItemUnitData
Rated voltagekV40.5
Rated currentA1250/1600
Rated frequencyHz50 or 60
Power frequency withstand voltage 1min(wet)(dry)kV80/95
Lightning impulse withstand voltage(peak voltage)kV185
Rated short circuit breaking currentkA31.5
Rated short circuit making current(peak value)kA80
Rated peak withstand currentkA80
4S short time withstand currentkA31.5
Rated operating sequenceO-0.1s-CO-3sCO-6sCO-60s recover
Rated short circuit current breaking timestimes30
Mechanical lifetimes20000
Permanent magnet mechanism control voltageVDC220
Secondary circuit 1min power frequency voltageKV2

circuit breaker main mechanical parameter
ItemUnitData
Contact opening distancemm16±1
Contact over travelmm4±0.5
Opening speedm/s1.4-1.8
Closing speedm/s0.4-0.8
Contact closing bounce timems≤5
Center distance between phasemm560±2
Triphase opening/closing asynchronousms≤2
Each phase conductive circuit resistanceμΩ<120
Closing timems25~45
Opening timems20~45
WeightKg300