0
indoor vacuum circuit breaker

24kV MV Indoor Vacuum Circuit Breaker with Permanent Mechanism/Switch for Switchgear, VAC68-24kV

VAC68-24kV
Delivery:
FOB
minimum order:
1 piece
Quantity:
Contact Now
add to cart

1. General description
   VAC68-24kV vacuum circuit breaker adopts permanent magnet operation mechanism, which is used to switch on and off various kinds of power loads. It is suitable for urban power grid, rural power grid, mine and railway power grid construction and transformation projects, especially for frequent operation within the working current range and occasions with certain requirements for short circuit operation times. This product absorbs advanced technology at home and abroad, and is perfect to combine the permanent magnet operation mechanism, vacuum interrupter and intelligent control. It has the characteristic of intelligence, high reliability, long service life and free maintenance. It is a green environmental protection product without pollution to the surrounding environment.

The Technical Specifications of this vacuum circuit breaker define its electrical and mechanical parameters for 24kV indoor switchgear applications. The indoor vcb model VAC68-24kV adopts a permanent magnet operation mechanism, used to switch on and off various kinds of power loads. This indoor vacuum circuit breaker is suitable for urban power grids, rural power grids, mine and railway power grid construction and transformation projects, especially for frequent operation within the working current range and occasions with certain requirements for short circuit operation times. The vacuum circuit breaker absorbs advanced technology at home and abroad, perfectly combining the permanent magnet operation mechanism, vacuum interrupter, and intelligent control. This indoor vcb features intelligence, high reliability, long service life, and maintenance-free operation. The indoor vacuum circuit breaker is a green environmental protection product without pollution to the surrounding environment. This vacuum circuit breaker is available in rated currents from 630A to 4000A, with rated short circuit breaking currents of 20, 25, 31.5, and 40kA. Each indoor vcb undergoes comprehensive testing to ensure reliable performance in demanding distribution networks. Proper installation of this indoor vacuum circuit breaker ensures long-term operational reliability in 24kV systems.

2. Main technical parameter

Item

Unit

Data

Rated voltage

kV

24

Rated frequency

Hz

50, 60

Rated current

A

630, 1250, 1600, 2000, 2500, 3150, 4000

Rated short circuit breaking current

kA

20, 25, 31.5, 40

Rated peak withstand current

kA

50, 63, 80, 100

Rated short time withstand current

kA

20, 25, 31.5, 40

Rated short circuit making current

kA

25, 63, 80, 100

Breaking times of short circuit current

times

50 (no more than 31.5kA) / 30 (40kA)

Rated operation sequence

O-0.3s-CO-180s-CO (no more than 31.5kA)
O-180s-CO-180s-CO (40kA)

Mechanical life

times

20,000

Rated current breaking times

times

20,000

Rated lightning impulse withstand voltage (full wave)

kV

125

Rated short time power frequency withstand voltage

kV/min

65

Rated short circuit duration

s

4

Rated operation voltage

V

DC110/220, AC110/220

Contact travel

mm

13±1

Contact over travel

mm

3.5±0.5

Closing speed

m/s

0.5-1.1

Opening speed

m/s

1.1-1.7

Contact bouncing duration at opening and closing operation

ms

≤3

Three phase closing and opening simultaneity

ms

≤2

Closing time

ms

20≤t≤75

Opening time

ms

13≤t≤65

Driving power voltage of permanent magnet mechanism

V

DC220

Energy storage time

s

<10

Closing control time

ms

≌110, ≌220

Opening control time

ms

≌110, ≌220

Main circuit resistance

μΩ

≤45

Phase to phase distance

mm

150/210/275(kA)

Send Message