1. General description
   VACZ1 series AC vacuum contactor is suitable for power system of AC tri-phase 50Hz, rated current 630 A and below, rated voltage 24kv, for remotely making and breaking circuit, frequently starting and controlling AC motor. It also could be combined with fuse and protector to replace vacuum circuit breaker.
   The vacuum contactor complies with GB/T 14808, IEC 60470 and JB/T 7122 standard, the main performance indicators have reached the international level.

The Technical Specifications of this vacuum contactor define its electrical and mechanical parameters for AC motor control and capacitor switching applications in medium-voltage power systems. This mv vacuum contactor is suitable for power systems of AC three-phase 50Hz with rated current up to 630A and rated voltage of 24kV, designed for remotely making and breaking circuits, frequently starting and controlling AC motors. The 24kv vacuum contactor can also be combined with fuses and protectors to replace vacuum circuit breakers in certain applications. This vacuum contactor complies with GB/T 14808, IEC 60470, and JB/T 7122 standards, with main performance indicators reaching international levels. The mv vacuum contactor is available in rated currents of 160A, 250A, 400A, and 630A for 24kV voltage class. This 24kv vacuum contactor offers making capacity of up to 6300A per 100 operations, make-break capacity of up to 5000A per 25 operations, and maximum breaking capacity of up to 6000A per 3 operations. Each vacuum contactor features a mechanical life of 100,000 operations and an electrical life of 10,000 operations. Proper installation of this mv vacuum contactor ensures reliable performance in switchgear and capacitor bank applications.

2. Main technical parameter

Item

Unit

VACZ1 160/24

VACZ1 250/24

VACZ1 400/24

VACZ1 630/24

Main circuit rated voltage

kV

24

24

24

24

Main circuit rated current

A

160

250

400

630

Main circuit current making capacity

A/100times

1600

2500

4500

6300

Main circuit make-break capacity

A/25times

1280

2000

3200

5000

Maximum breaking capacity

A/3times

3200

4000

4500

6000

Mechanical life

Thousand times

100

100

100

100

Engineering lock life

Thousand times

10

10

10

10

Electrical life

25

25

25

25

Permanent magnet mechanism life

Thousand times

10

10

10

10

Power-frequency withstand voltage of main circuit

kV

65

65

65

65

Phase to phase/phase to earth power frequency withstand voltage

65

65

65

65

Lightning impulse withstand voltage

kV

90

90

90

90

Rated operating frequency

times/h

150

150

150

150

Rated operating frequency of permanent magnet mechanism

times/h

30

30

30

30

Terminal pressure

N

>100

>100

>100

>100

Clearance between open contacts

mm

12±1

12±1

12±1

12±1

Over travel

mm

2±5

2±5

2±5

2±5

Main circuit resistance

μΩ

≤180

≤160

≤140

≤120